Shoes/Leather Test Machines

UP-4016 ISO 6452 Automotive Interior Trim Fogging Tester


ISO 6452 AUP-4016 ISO 6452 Automotive Interior Trim Fogging Tester(图1)UP-4016 ISO 6452 Automotive Interior Trim Fogging Tester(图2)utomotive Interior Trim Fogging Tester

Applicable industry

 

It is professionally designed for the fogging characteristics evaluation of volatile constituents of decorating materials used in cars and aircrafts, e.g. plastic articles, polyurethane, textiles, leather, adhesives, nonwovens and thermal forming elastomers at high temperature conditions. Furthermore it could be used for the fogging phenomenon test of high intensity discharge (HID) headlamps of cars.

Standards compliant

ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X 83231, NES M0161, D45 1727, GM 9305P, TSM 0503G

Professional Technology 1. Wide range and high precision of temperature control device to support the combinations of non-standard test conditions 2. 6 test stations can perform specimen test or blank test simultaneously 3. This instrument ensures accurate and reliable test data through stable running condition

Specification

Temperature Range of High-Temperature Bath

45~160°C (room temperature~280°C is optional)

Temperature Range of   Low-Temperature Bath

-28~100°C

Accuracy

±0.1 °C

High-Temperature Bath Power

3.0KW

Low-Temperature Bath Power

2.0KW

Circular Flow

15L/min

Size of High-Temperature Bath

600 mm (W) x 425 mm (H) x 600 mm (D)

Size of Low-Temperature Bath

230 mm (W) x 420 mm (H) x 610 mm (D)

Net Weight of High-Temperature   Bath

48 kg

Net Weight of Low-Temperature   Bath

28 kg

Power Supply

220VAC 50Hz / 120VAC 60Hz

Three Test Methods

Gloss Method: The specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value could be obtained by calculating and comparing the gloss values occurred before and after condensation process.

Haze Method: The specimen is heated in the beaker and its volatile constituents are condensed on the cooling glass plate. The fogging value of the specimen could be obtained by calculating and comparing the fogging values occurred before and after condensation process.

Weighing Method: The specimen is heated in the beaker and its volatile constituents are condensed on the cooling aluminum foil. The fogging value-the weight of condensed constituents could be obtained by analyzing the weight changes of aluminum foil occurred before and after condensation process.

Configurations

Standard Configurations: Instrument, Constant Temperature Control Device, Gloss Meter, Sample Clamp Ring, Beaker, Fluorine Rubber O-ring, Rubber Fixing Ring, Rectangular Glass Plate, Round Glass Plate, Aluminum Foil, Round Sample Cutter of Aluminum Foil, Lid, Stand of Glass Plate, Round Sample Cutter and Accessory Stand.



Optional Parts: Haze Meter, Analytical Balance (0.01 mg), Beaker, Fluorine Rubber O-ring, Rectangular Glass Plate, Round Glass Plate, Aluminum Foil, Round Sample Cutter of Aluminum Foil, Stand of Glass Plate, Heating Fluid, DIDP and DOP