Generation Equipment Solvent Testing Gas Chromatography

Product Description

 

   This machine is carried out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing;Test the pureness and quality of organic solvents.

   Gas chromatography (GC), is a common type of chromatography used in analytical chemistry for separating and analyzing compounds that can be vaporized without decomposition. Typical uses of GC include testing the purity of a particular substance, or separating the different components of a mixture (the relative amounts of such components can also be determined).

 

Design standard:   GB/T10004-2008, YBB00132002

 Characteristics:

   1.With higher ratio of function and reasonable price, economic and efficient

   2.The design of the cellular integral structure is convenient for installation.

   3.It can be connected to the chromatogram data work station so as to greatly improve the working efficiency.

   4.With FID detector

   5.With the flexible design of the packed column and capillary column injection ports.

   6.Packed column and capillary column sample injectors can be selected as per actual situations. Wide column box (300×300×200mm)

   7.In order to meet complicated analytic task, it makes use of various chromatographic columns so as to offer convenience and widen the range of the analytic samples. The advanced noise suppression system can fully eliminate the fan noise under the chromatogram working state, so as to provide you a comfortable and quiet working atmosphere.

   8.The sampling device is completely vitrified with two modes of rapid vaporizing and column sample injection.

   9.Bran-new pressure stabilization and various air circuit system

   10.The air circuit has three different kinds of forms: Single, double and triple. It can match six-way valve, blow back, and precut equipment and so on according to the users’ demands. It adopts new type pressure regulation system to ensure the re-productivity of equipment.

   11.Reforming furnace can be equipped to implement microanalysis of CO and CO2.

   12.Cracking furnace can be equipped to do double eight-step temperature rise with microcomputer control, man-machine conversation and simple application.

   13.Advanced temperature control system

   14.Adopt microcomputer control and man-machine conversation to indicate various needed temperatures of the temperature column box.

   15.Column box temperature control scope: (room temperature +10°C) - 400°C, eight-step temperature rise.The speed is 0 - 30°C/min (increase 0.1°C/min), and the temperature control precision is 0.1%.

 

Product Parameters

Thermal   conductivity detector (TCD)

S≥5000mv.ml/mg (benzene)

Electron capture detector (ECD)

M≤2×10-13g/ml (r-666)

Flame-photometric detector (FPD)

Ms≤5×10-11g/sec (thiophene) Mp≤1×10-11g/sec   (1605)

Nitrogen and phosphorous detector (NPD)

Mn:1×10-13g/sec      Mp:1×10-13g/sec

Temperature

10~400°C

Temperature percision

≤0.1°C

Temperature rise speed

0.1~40°C/min

Hydrogen flame ionization detector

M≤1×10-11 G/S